Notes on Pleated Membrane Filters
Installation Guide for Filter Cartridges
The air filter cartridges used in modular filtration systems feature a pleated design. They utilize ultra-fine glass fiber or PTFE (polytetrafluoroethylene) media, supported externally by stainless steel or housed within high-temperature-resistant casings. These cartridges offer high dirt-holding capacity and low pressure drop, and are easy to install and replace. At an inlet air pressure of 0.2 MPa and a pressure drop of 0.008 MPa, each 10-inch (250 mm) filter cartridge provides a flow rate of 300 Nm³/h.
(1) After opening the filter element packaging, carefully inspect the element to ensure its surface is smooth and free of damage, and verify that the silicone rubber rings are intact.
(2) Never open the filter housing while it is under pressure. Ensure the compressed air supply is isolated and the housing is completely depressurized before attempting to open it.
(3) Once the old filter element has been removed, clean the connection socket on the filter housing using a non-corrosive cleaning agent. Allow the socket to dry completely before installing the new filter element.
(4) Open the plastic bag containing the filter element (at the end featuring the two rubber rings) without removing the bag entirely; expose only the two rubber rings and apply an appropriate lubricant to them. Grip the opposite end of the filter element firmly with both hands, insert the tip into the bottom of the socket, and rotate it clockwise to lock it into place. Do not hold the filter element by its topmost end (the tail section with the raised boss) during installation, as this may cause permanent damage to the element.
(5) After all filter elements have been installed, remove all plastic packaging and attach the retaining chuck at the tail end. Be careful not to overtighten the locking nut, as this could crush or damage the filter elements.
Precautions for Filter Sterilization
(1) The saturated steam used must be processed through a steam filter to remove impurities and condensate. Only after this purification should it be used to sterilize the air filter; otherwise, the filter element may suffer premature damage.
(2) When using saturated steam for sterilization, it is recommended to maintain the steam pressure between 198–270 kPa and the temperature between 120–130°C.
(3) During steam sterilization, all valves must be fully opened to ensure no “dead zones” remain. The sterilization process should last 30–40 minutes. Upon completion, compressed air must be introduced slowly; an excessive flow rate could cause friction against the filter medium, potentially leading to a safety incident.
(4) During the introduction of air, the pressure drop across the filter must be strictly controlled to prevent reverse pressure. It is essential to ensure that the pressure upstream of the filter membrane never falls below the pressure downstream, as this could cause the membrane tubes to deform.
(5) Following steam sterilization—and provided the process allows—the filter’s inlet valve should be fully opened, and air should be passed through for approximately 0.5 hours to ensure the filter is completely dry before it is put into operation. Operating a filter while it is still damp may create a risk of microbial contamination in the process fluid.
(6) After use, the inlet and outlet valves of the steam filter must be closed, and the bottom drain valve should be fully opened. This prevents potential microbial contamination caused by leaks in the steam valves.
(7) If superheated steam is used to sterilize a filter, it must first be subjected to pressure and temperature reduction to meet the specific requirements for steam used in the fermentation industry.